4420 Falls Terrace SE

Ward 7 ANC 7E 4 units Built c. 1944 Map ↗ Nearby buildings → Print flyer ↗
17
Violations (last 2 yrs)
$31,111
Fines (last 2 yrs)
17
Total violations
$31,111
Total fines
Tenant here? Report issues anonymously — and find out if your neighbors are going through the same thing

Violations

12-G DCMR § 704.2
Failure to install or maintain single- or multiple-station smoke alarms in Group I-1 and R occupancies, and dwellings not regulated as Group R occupancies, regardless of occupant load in each room used for sleeping purposes
avg $2,483
+ I can confirm this is still happening
Show details · 4 occurrences · $9,933 in fines
Jan 9, 2026 $2,499 CAP 26NOIE-INS-01474 Sleeping room 1 Interior
Jan 9, 2026 $2,499 CAP 26NOIE-INS-01474 Sleeping room 2 Interior
Dec 31, 2025 $2,499 CAP 26NOIE-INS-01345 Sleeping Room Interior
+1 more
Sep 17, 2024 $2,436 CAP 24NOIE-INS-04850 Sleeping Room 1
12-G DCMR § 305.3
Failure to correct cracked or loose plaster, holes, decayed wood, water damage and/or other defective surface conditions
avg $620
+ I can confirm this is still happening
Show details · 3 occurrences · $1,859 in fines
Dec 22, 2025 $625 CAP 26NOIR-INS-01753 Bathroom 1
Dec 22, 2025 $625 CAP 26NOIR-INS-01753 Living room 1
Sep 17, 2024 $609 CAP 24NOIR-INS-06891 Bathroom 1
12-G DCMR § 310.2
Failure to install an approved carbon monoxide alarm in the immediate vicinity of the bedrooms in dwelling units located in a building containing a fuel-burning appliance or a building which has an attached garage
avg $2,499
+ I can confirm this is still happening
Show details · 2 occurrences · $4,998 in fines
Jan 9, 2026 $2,499 CAP 26NOIE-INS-01474 Hallway Interior
Dec 31, 2025 $2,499 CAP 26NOIE-INS-01345 Hallway Interior
12-G DCMR § 704.2
Failure to install or maintain single- or multiple-station smoke alarms in Group I-1 and R occupancies, and dwellings not regulated as Group R occupancies, regardless of occupant load on the ceiling or wall outside of each separate s
avg $2,499
+ I can confirm this is still happening
Show details · 2 occurrences · $4,998 in fines
Jan 9, 2026 $2,499 CAP 26NOIE-INS-01474 Hallway Interior
Dec 31, 2025 $2,499 CAP 26NOIE-INS-01345 Hallway Interior
11-A DCMR § 302.1
(Failure to obtain a certificate of occupancy or use beyond the scope of the certificate of occupancy)
avg $2,499
+ I can confirm this is still happening
Show details · 2 occurrences · $4,998 in fines
Jan 9, 2026 $2,499 CAP 26NOIE-INS-01474 Entire Unit Interior/Exterior
Dec 31, 2025 $2,499 CAP 26NOIE-INS-01345 Entire Unit Interior/Exterior
Show 3 more violation types
IPMC § 604.3
Failure to correct electrical system that constitutes a hazard to the occupants or the structure
avg $1,234
+ I can confirm this is still happening
Show details · 2 occurrences · $2,467 in fines
Dec 22, 2025 $1,249 CAP 26NOIR-INS-01753 Bathroom 1
Sep 17, 2024 $1,218 CAP 24NOIE-INS-04850 Cooking room 1
IPMC § 305.1
Failure to maintain interior of structure and equipment therein in good repair, structurally sound and in sanitary condition
+ I can confirm this is still happening
Show details · 1 occurrence · $1,249 in fines
Dec 22, 2025 $1,249 CAP 26NOIR-INS-01753 Sleeping Room 1
IPMC § 605.2
Failure to have ground fault circuit interrupter protection for every new bathroom receptacle outlet
+ I can confirm this is still happening
Show details · 1 occurrence · $609 in fines
Sep 17, 2024 $609 CAP 24NOIR-INS-06891 Bathroom 1

Do you live here?

Report issues anonymously — takes 30 seconds, and you'll be able to see if your neighbors are dealing with the same thing.

Report a different issue