Failure maintain fire extinguishers in accordance with NFPA 10 as referenced in the Fire Code
avg $2,4993×
+ I can confirm this is still happening
Show details · 3 occurrences
· $7,497 in fines
Nov 3, 2025$2,499CAP 26NOIE-INS-00496Common hallway1
Nov 3, 2025$2,499CAP 26NOIE-INS-00496Common hallway2
Nov 3, 2025$2,499CAP 26NOIE-INS-00496Common hallway3
IPMC § 603.1
Failure to properly install and maintain mechanical appliances, fireplaces, solid fuel-burning appliances, cooking appliances, and water heating appliances in a safe working condition capable of performing the intended function
+ I can confirm this is still happening
Show details · 1 occurrence
· $1,249 in fines
Nov 4, 2025$1,249CAP 26NOIE-INS-00539Cooking roomInterior
12-G DCMR § 602.2
Failure to provide heating facilities for residential occupancies which are capable of maintaining a room temperature of 68?F20?C in all habitable rooms, bathrooms and toilet rooms.
+ I can confirm this is still happening
Show details · 1 occurrence
· $2,499 in fines
Nov 4, 2025$2,499CAP 26NOIE-INS-00539Entire UnitInterior
12-G DCMR § 305.4
Failure to maintain stairs and/or other walking surfaces in sound condition, good repair and free from hazardous conditions
+ I can confirm this is still happening
Show details · 1 occurrence
· $1,249 in fines
Nov 4, 2025$1,249CAP 26NOIR-INS-00903BathroomInterior
IPMC § 403.2
Failure to provide proper ventilation for bathroom or toilet room
+ I can confirm this is still happening
Show details · 1 occurrence
· $625 in fines
Nov 4, 2025$625CAP 26NOIR-INS-00903BathroomInterior
Show 5 more violation types
12-G DCMR § 704.2
Failure to install or maintain single- or multiple-station smoke alarms in Group I-1 and R occupancies, and dwellings not regulated as Group R occupancies, regardless of occupant load on the ceiling or wall outside of each separate s
+ I can confirm this is still happening
Show details · 1 occurrence
· $2,499 in fines
Nov 3, 2025$2,499CAP 26NOIE-INS-00485HallwayInterior
IPMC § 502.1
Failure to maintain bathtub, shower, lavatory, water closet or kitchen sink in a sanitary, safe working condition
+ I can confirm this is still happening
Show details · 1 occurrence
· $625 in fines
Nov 3, 2025$625CAP 26NOIR-INS-00824BathroomInterior
12-G DCMR § 704.2
Failure to install or maintain single- or multiple-station smoke alarms in Group I-1 and R occupancies, and dwellings not regulated as Group R occupancies, regardless of occupant load in each room used for sleeping purposes
+ I can confirm this is still happening
Show details · 1 occurrence
· $2,436 in fines
May 24, 2024$2,436CAP 24NOIE-INS-03336Sleeping room 2Interior
IPMC § 505.4
Failure to provide water heating facilities which provide water at a minimum temperature of 110?F 43? C .
+ I can confirm this is still happening
Show details · 1 occurrence
· $1,218 in fines
May 24, 2024$1,218CAP 24NOIR-INS-04793Cooking roomInterior
IPMC § 605.2
Failure to have receptacle outlets with the appropriate faceplate covers for the location
+ I can confirm this is still happening
Show details · 1 occurrence
· $609 in fines
May 24, 2024$609CAP 24NOIR-INS-04793Cooking roomInterior