316 34 th Street SE

Ward 7 ANC 7B 4 units Built c. 1942 Map ↗ Nearby buildings → Print flyer ↗
14
Violations (last 2 yrs)
$23,581
Fines (last 2 yrs)
20
Total violations
$28,769
Total fines
Tenant here? Report issues anonymously — and find out if your neighbors are going through the same thing

Violations

12-G DCMR § 305.3
Failure to correct cracked or loose plaster, holes, decayed wood, water damage and/or other defective surface conditions
avg $579
+ I can confirm this is still happening
Show details · 4 occurrences · $2,314 in fines
Feb 16, 2026 $638 CAP 26NOIR-INS-02982 Bathroom Interior
Feb 16, 2026 $638 CAP 26NOIR-INS-02982 Utility Closet Interior
Sep 9, 2019 $519 CAP 19ENF-HOUS-05875 Kitchen Interior
+1 more
Sep 9, 2019 $519 CAP 19ENF-HOUS-05875 Sleeping room 2 Interior
IPMC § 304.13
Failure to maintain windows, skylights, door or frame in sound condition, good repair and weather tight
avg $638
+ I can confirm this is still happening
Show details · 3 occurrences · $1,914 in fines
Feb 16, 2026 $638 CAP 26NOIR-INS-02982 Living room Interior
Feb 16, 2026 $638 CAP 26NOIR-INS-02982 Sleeping room 1 Interior
Feb 16, 2026 $638 CAP 26NOIR-INS-02982 Sleeping room 2 Interior
12-G DCMR § 310.2
Failure to install an approved carbon monoxide alarm in the immediate vicinity of the bedrooms in dwelling units located in a building containing a fuel-burning appliance or a building which has an attached garage
avg $2,549
+ I can confirm this is still happening
Show details · 2 occurrences · $5,098 in fines
Mar 16, 2026 $2,549 CAP 26NOIE-INS-02665 Kitchen Interior
Feb 16, 2026 $2,549 CAP 26NOIE-INS-02138 Hallway Interior
12-G DCMR § 704.2
Failure to install or maintain single- or multiple-station smoke alarms in Group I-1 and R occupancies, and dwellings not regulated as Group R occupancies, regardless of occupant load in each room used for sleeping purposes
avg $2,549
+ I can confirm this is still happening
Show details · 2 occurrences · $5,098 in fines
Mar 16, 2026 $2,549 CAP 26NOIE-INS-02665 Sleeping room 1 Interior
Mar 16, 2026 $2,549 CAP 26NOIE-INS-02665 Sleeping room 2 Interior
IPMC § 502.1
Failure to maintain bathtub, shower, lavatory, water closet or kitchen sink in a sanitary, safe working condition
avg $519
+ I can confirm this is still happening
Show details · 2 occurrences · $1,038 in fines
Sep 9, 2019 $519 CAP 19ENF-HOUS-05875 Bathroom Interior
Sep 9, 2019 $519 CAP 19ENF-HOUS-05875 Kitchen Interior
Show 7 more violation types
12-G DCMR § 704.1.3
Failure to keep all required portable fire extinguishers maintained in an efficient and safe operating condition
+ I can confirm this is still happening
Show details · 1 occurrence · $2,549 in fines
Mar 16, 2026 $2,549 CAP 26NOIE-INS-02665 Hallway 1
IPMC § 501.2
Failure by owner to provide required plumbing facilities and plumbing fixtures in a dwelling unit.
+ I can confirm this is still happening
Show details · 1 occurrence · $1,274 in fines
Mar 16, 2026 $1,274 CAP 26NOIE-INS-02665 Kitchen Interior
12-G DCMR § 702.4
Failure to maintain the required emergency escape openings in accordance with the code in effect at the time of construction
+ I can confirm this is still happening
Show details · 1 occurrence · $2,549 in fines
Mar 16, 2026 $2,549 CAP 26NOIE-INS-02665 Sleeping Room Interior
12-G DCMR § 704.2
Failure to install or maintain single- or multiple-station smoke alarms in Group I-1 and R occupancies, and dwellings not regulated as Group R occupancies, regardless of occupant load on the ceiling or wall outside of each separate s
+ I can confirm this is still happening
Show details · 1 occurrence · $2,549 in fines
Feb 16, 2026 $2,549 CAP 26NOIE-INS-02138 Living room Interior
IPMC § 305.1
Failure to maintain interior of structure and equipment therein in good repair, structurally sound and in sanitary condition
+ I can confirm this is still happening
Show details · 1 occurrence · $1,274 in fines
Feb 16, 2026 $1,274 CAP 26NOIR-INS-02982 Cooking room Interior
IPMC § 601.2
Failure by owner to provide or maintain the required mechanical and electrical facilities
+ I can confirm this is still happening
Show details · 1 occurrence · $1,037 in fines
Sep 9, 2019 $1,037 CAP 19ENF-HOUS-05875 Kitchen Interior
12-G DCMR § 704.2
Failure to install or maintain single- or multiple-station smoke alarms in Groups R-2, R-3, and R-4, and dwellings not regulated as Group R occupancies, regardless of occupant load in each room used for sleeping purposes
+ I can confirm this is still happening
Show details · 1 occurrence · $2,075 in fines
Sep 9, 2019 $2,075 CAP 19ENF-HOUS-05875 Sleeping room 1 Interior

Do you live here?

Report issues anonymously — takes 30 seconds, and you'll be able to see if your neighbors are dealing with the same thing.

Report a different issue

What you can do

🏘️
Connect with others in your building
Create a free account to anonymously share what's happening and see if your neighbors are dealing with the same issues. Your identity is never shared.
Create free account →
📋
Print a flyer for your building
A one-page summary of this building's violation history — leave it in the lobby or elevator, or slip it under a neighbor's door.
Print flyer →